Data centre words
150 terms. The words of data centres, power, cooling and networks, in plain language.
#
- 24/7 carbon-free energy
- Matching every hour of a data centre's power use with carbon-free electricity on the same grid, rather than balancing the year as a whole.
- 2N
- A redundancy level with two complete, independent systems, each able to carry the whole load on its own.
A
- A and B feeds
- Two independent power paths to each rack, so equipment with two power supplies keeps running if one path fails.
- Absorption
- The amount of data centre capacity, in megawatts, leased and occupied in a market over a period; vacancy is the share left empty.
- Adiabatic cooling
- Spraying or wicking water into incoming air, or over a cooler's coils, so it evaporates and lowers the air temperature on hot days.
- AI factory
- A data centre built mainly to train and run AI models, a term popularised by Nvidia for halls that turn power and data into AI output.
- AI training cluster
- A large group of GPUs joined by a fast network so that they can work together on training one AI model.
- Air-side economiser
- A system that brings filtered outside air into the data halls when it is cool enough, and sends hot air out.
- Aisle containment
- Doors, roofs or curtains that close off a hot or cold aisle so that hot and cold air cannot mix.
- ASHRAE thermal guidelines
- Industry guidance from the US engineering society ASHRAE on the temperature and humidity range for air entering IT equipment.
- Automatic transfer switch
- A switch that moves a load from one power source to another, such as from the grid to a generator, without anyone pressing a button.
- Autonomous system
- A network, or group of networks, under one operator that presents a single routing policy to the internet, identified by an AS number.
- Availability
- The share of time a system is working, often written as a number of nines: 99.999 per cent is "five nines".
- Availability zone
- One or more data centres within a cloud region with their own power, cooling and networking, placed so that a fault in one zone should not affect another.
B
- Battery energy storage
- Large banks of batteries that store electricity, used at data centres to back up, support the grid or replace some diesel generators.
- Behind the meter
- Power supplied to a data centre directly from a generator on or next to the site, without passing through the public grid.
- BGP
- The routing protocol that networks use to tell each other which internet addresses they can reach, the glue that holds the internet together.
- Blanking panel
- A plain plate that covers an empty slot in a rack, so that hot air cannot leak back to the front through the gap.
- BMS
- The control system that monitors and runs a data centre's mechanical and electrical plant: chillers, pumps, fans, switchgear and generators.
- Build-to-suit
- A data centre that a developer builds to one tenant's design and then leases to that tenant on a long contract.
- Busway
- Overhead metal bars in a casing that carry power along a row of racks, with plug-in boxes tapped off for each rack.
C
- Cabinet
- A rack with side panels, a lockable front and back door and a roof, the usual way space is rented in a colocation hall.
- Cable landing station
- The building on the shore where a subsea cable comes out of the sea and connects to land networks and power.
- Cable tray
- Open metal channels hung above the racks, or below a raised floor, that carry power and data cables through a hall.
- Cage
- A locked mesh enclosure on a shared data hall floor that holds one customer's group of cabinets.
- Campus
- A site with several data centre buildings sharing land, a substation, fibre routes and security.
- Carrier hotel
- A building, often in a city centre, where many telecom networks have equipment and connect to one another.
- Carrier-neutral
- A data centre not owned by a telecom carrier, where any network may connect and customers can choose among them.
- CDN
- A network of servers in many cities that stores copies of websites, video and software close to users, so they load faster.
- CDU
- A unit of pumps, filters and a heat exchanger that circulates coolant to liquid-cooled racks and keeps it separate from the building's water.
- Chilled water system
- A loop of cooled water pumped from a central plant to cooling units in the halls, carrying heat back to chillers or coolers.
- Chiller
- A machine that cools water using a refrigeration cycle, supplying chilled water to cooling units around a data centre.
- Cloud on-ramp
- A private connection from a customer's network or data centre straight into a public cloud, bypassing the public internet.
- Cloud region
- A geographic area, such as a city or country, where a cloud provider runs a cluster of data centres, usually split into availability zones.
- Colocation
- Renting space, power and cooling in a data centre run by someone else, for servers that the customer owns.
- Commissioning
- The staged testing of a new data centre's power, cooling and controls, ending in a full test of everything working together.
- Concurrently maintainable
- A design in which any piece of equipment or path can be taken out for planned maintenance without shutting down the IT load.
- Cooling tower
- An outdoor tower that removes heat from water by evaporating some of it into the air.
- CRAC
- An air conditioner for a computer room with its own built-in refrigeration compressor.
- CRAH
- A cooling unit for a computer room that uses chilled water from a central plant rather than its own compressor.
- Critical IT load
- The power drawn by the IT equipment itself (servers, storage and network), not counting cooling, lighting and losses.
- Cross-connect
- A physical cable, usually fibre, linking two customers' equipment within the same data centre.
- CUE
- A data centre's carbon dioxide emissions from energy use divided by the energy used by its IT equipment.
D
- Dark fibre
- Optical fibre cable leased without any equipment attached, which the customer lights with its own lasers and electronics.
- Data centre
- A building, or part of one, that houses servers, storage and network equipment with the power, cooling and security to keep them running.
- Data centre REIT
- A listed company that owns data centres and, under tax rules for real estate investment trusts, pays out most of its income to shareholders.
- Data hall
- A large room in a data centre filled with rows of racks, served by its own power and cooling systems.
- Data localisation
- Rules that require certain data to be stored, or processed, within a country's borders.
- DCIM
- Software that tracks a data centre's assets, space, power and cooling in real time and helps plan where new equipment can go.
- Delta T
- The difference in temperature between the air or liquid going into equipment and coming out of it.
- Demand response
- Reducing or shifting electricity use when the grid is under strain, often for payment.
- Diesel generator
- A diesel engine joined to an alternator, kept ready to power a data centre for hours or days if the grid fails.
- Direct expansion
- Cooling in which refrigerant expands and evaporates directly in the coil that cools the air, as in a home air conditioner.
- Direct-to-chip liquid cooling
- Cooling in which liquid flows through metal cold plates fixed on top of the hottest chips, carrying heat straight out of the server.
- District heating
- A network of insulated pipes that carries hot water from central sources to heat many buildings in a town.
- Diverse routes
- Separate physical paths for fibre or power into a site, so one cut cable or failed line cannot isolate it.
- Dry cooler
- A large outdoor radiator with fans that cools a water or glycol loop using only air, without evaporating water.
- DWDM
- A technology that sends many separate signals down one optical fibre, each on its own colour of light.
E
- Edge data centre
- A small data centre placed close to the people or machines it serves, to cut latency and the traffic sent to distant sites.
- Embodied carbon
- The greenhouse gases emitted in making a data centre's materials and equipment and building it, as opposed to running it.
- EN 50600
- The European standard series for data centre facilities, covering design, power, cooling, security and efficiency, with four availability classes.
- Enterprise data centre
- A data centre owned and run by a company for its own systems, rather than for rent to others.
- ERE
- A version of PUE that subtracts the energy a data centre exports for reuse, such as heat sent to a district heating network.
- Evaporative cooling
- Cooling air or water by evaporating water into it, the main way many large data centres in dry climates keep cool.
F
- Fault tolerant
- A design that keeps the IT load running through any single unplanned failure, such as a fire in a plant room or a failed switchboard.
- Fire suppression
- Systems that put out a fire in a data hall, usually by flooding it with an inert or clean gas, or by sprinklers that hold water until needed.
- Flywheel UPS
- A UPS that stores energy in a spinning wheel instead of batteries; a diesel rotary UPS joins a flywheel, motor-generator and diesel engine in one unit.
- Free cooling
- Using cold outside air or water to cool a data centre, so that energy-hungry refrigeration can be switched off or turned down.
- Fuel cell
- A device that makes electricity from a chemical reaction of fuel and oxygen, without burning, used at some data centres for main or backup power.
G
- Gigawatt
- A thousand megawatts, the scale of the largest AI data centre campuses now being built and of a large power station.
- GPU
- A processor with thousands of small cores, first made for graphics, now the main engine for training and running AI models.
- GPU as a service
- Renting time on GPUs in someone else's data centre, by the hour or under a reserved contract, instead of buying them.
- GPU density
- How many GPUs, and so how much power and heat, are packed into each rack or hall.
- Grey space
- The parts of a data centre that hold electrical and mechanical plant: switch rooms, UPS and battery rooms, chillers, generators and pumps.
- Grid connection
- The agreement and physical link that lets a data centre draw a set amount of power from the grid, now the main limit on where data centres can be built.
H
- Heat reuse
- Capturing the heat that a data centre removes from its servers and using it to warm homes, offices, pools or greenhouses.
- High density
- A hall or rack that draws much more power per square metre than a standard design, typically above 20 kW per rack.
- Hot aisle and cold aisle
- A layout where racks face each other in pairs of rows, so cold air is fed into one aisle and hot exhaust collects in the next.
- HVO
- A renewable diesel fuel made from waste fats and vegetable oils, which can replace fossil diesel in data centre generators.
- Hyperscale data centre
- A very large data centre, or campus of them, built for one of the big cloud and internet companies, usually tens to hundreds of megawatts.
- Hyperscaler
- One of the handful of companies that run cloud and internet services at the largest scale: Amazon, Microsoft, Google, Meta, Oracle, Alibaba, Tencent and a few others.
I
- Immersion cooling
- Cooling servers by submerging them in tanks of a non-conductive liquid, which takes heat from every component.
- In-row cooling
- Cooling units placed between the racks in a row, drawing hot air from the hot aisle and blowing cooled air into the cold aisle close by.
- Inference
- Running a trained AI model to answer requests, as opposed to training it.
- InfiniBand
- A high-speed, low-latency network technology used to link servers in supercomputers and AI training clusters.
- Interconnection
- Direct physical links between networks, clouds and companies inside a data centre, so traffic can pass between them without the public internet.
- Interconnection queue
- The waiting list of projects, both power plants and large loads such as data centres, seeking to connect to the grid.
- Internet exchange point
- A shared network switch, spread across data centres in a city, where many networks connect once and exchange traffic with each other.
- IP transit
- A paid service in which a larger network carries a customer's traffic to and from the rest of the internet.
K
- kW per rack
- The electrical power drawn by one rack, the usual measure of how dense a data hall is.
L
- Latency
- The time it takes data to travel from one point to another and, for round-trip time, to get a reply.
- Lithium-ion UPS battery
- Lithium-ion batteries, now replacing lead-acid in many UPS systems because they are smaller, lighter and last longer.
- Load bank
- A portable set of electric heaters that draws a set amount of power, used to test generators, UPS systems and cooling before real servers arrive.
M
- Mantrap
- A small room with two interlocked doors, so that only one person at a time can pass into a secure area after checks.
- Medium voltage
- Electricity at roughly 1 kV to 35 kV, the level at which power is usually distributed around a data centre site.
- Meet-me room
- A secure room in a carrier hotel or colocation data centre where networks bring in their fibre and connect to each other.
- Megawatt
- A million watts, the unit in which data centre capacity is usually given.
- Modular data centre
- A data centre built from factory-made modules, such as containers or skids holding power and cooling, put together on site.
N
O
- On-site gas turbines
- Gas-fired turbines or engines built at a data centre to supply its main power, often while it waits for a grid connection.
- Optical transceiver
- A small module that turns electrical signals into light for fibre and back again, plugged into switches and servers.
P
- PDU
- A unit that distributes power to IT equipment: a strip of sockets in a rack, or a larger cabinet feeding rows of racks.
- Peering
- An arrangement in which two networks exchange traffic between their own customers directly, usually without either paying the other.
- Point of presence
- A place, usually a rack or cage in a data centre, where a network has equipment and customers or other networks can connect to it.
- Power purchase agreement
- A long-term contract to buy electricity, often from a new wind or solar farm, at an agreed price.
- Powered shell
- A data centre building delivered with its structure and a connection to grid power, but without the internal electrical and cooling fit-out.
- Pre-leasing
- Signing a tenant for data centre capacity before it is built or finished.
- Private network interconnect
- A dedicated link between two networks, usually by cross-connect in a shared data centre, used when they exchange a lot of traffic.
- Private suite
- A walled room inside a data centre leased to one customer, with its own access control and often its own cooling and power.
- Public cloud
- Computing, storage and software rented over the internet by the hour or by use, running in a provider's data centres.
- PUE
- Total energy used by a data centre divided by the energy used by its IT equipment; 1.0 would mean no energy spent on cooling or losses.
R
- Rack
- A standard metal frame, usually 19 inches wide and about two metres tall, into which servers, switches and other equipment are bolted.
- Rack unit
- The unit of height for rack equipment: 1U is 1.75 inches, or 44.45 mm.
- Raised floor
- A floor of removable tiles on pedestals, set above the concrete slab, with space beneath for cold air and cables.
- Rear-door heat exchanger
- A rack door fitted with a water-cooled coil, so hot exhaust air is cooled as it leaves the back of the rack.
- Redundancy
- Spare capacity or duplicate paths in a data centre's power and cooling, so a failure or maintenance does not stop the IT load.
- Remote hands
- A service in which the data centre's own staff do simple physical tasks on a customer's equipment, such as rebooting a server or swapping a cable.
- Renewable energy certificate
- A certificate showing that one megawatt-hour of electricity was made from a renewable source, which can be bought and claimed separately from the power.
- Retail colocation
- Colocation sold in small amounts, by the cabinet or cage, to many customers sharing a hall, often with many network connections.
- Route server
- A server at an internet exchange that collects routes from members and passes them on, so each member can peer with many others through one session.
S
- Sale and leaseback
- A deal in which a company sells its own data centre to an operator or investor and then rents it back.
- Seawater and lake cooling
- Using cold water from the sea, a lake or a river to cool a data centre, returning it slightly warmer.
- Server
- A computer built to run continuously in a rack and provide computing, storage or services to other computers over a network.
- Service level agreement
- The part of a data centre contract that sets the promised availability, temperatures and response times, and the credits owed if they are missed.
- Single point of failure
- Any part of a system whose failure alone would stop the whole system.
- Slab floor
- A data hall where racks stand directly on the concrete, with power, cabling and cooling delivered from above.
- Small modular reactor
- A nuclear reactor smaller than a conventional plant, up to about 300 MW of electricity, designed to be built in factories and installed in modules.
- Sovereign cloud
- Cloud or AI computing run within a country, under its laws and often by local companies, so that data and control stay at home.
- Spine-and-leaf
- A data centre network layout in which every rack switch (leaf) connects to every core switch (spine), so any two servers are a fixed number of hops apart.
- Static transfer switch
- An electronic switch that moves a load between two power sources in a few milliseconds, fast enough that servers do not notice.
- Stranded capacity
- Power or cooling capacity that has been built and paid for but cannot be used, because of how space, cooling or circuits are laid out.
- Structured cabling
- A planned, standard system of copper and fibre cables and patch panels connecting racks, rooms and the meet-me room.
- Subsea cable
- A fibre optic cable laid on the seabed between countries and continents, carrying almost all intercontinental internet traffic.
- Substation
- A yard of transformers and switchgear where high-voltage grid power is stepped down to a voltage a data centre can use.
- Switchgear
- Cabinets of circuit breakers, switches and protection relays that route, isolate and protect the electrical supply.
T
- Tenant
- The company that leases space and power in a data centre and puts its equipment there.
- Thermal design power
- The amount of heat, in watts, that a chip is designed to give off under heavy load, which its cooling must remove.
- TIA-942
- A US standard for data centre telecommunications and infrastructure, first published in 2005, with four rating levels.
- Transformer
- A device that changes electricity from one voltage to another, used at every step from the grid to the server.
- Two-phase immersion
- Immersion cooling in which the fluid boils on hot chips and condenses on a cold coil above, carrying heat by evaporation.
U
- UPS
- Equipment that keeps power flowing to IT loads without a break, using batteries or a flywheel, while the generators start after a grid failure.
- Uptime Institute Tier
- The Uptime Institute's four-level classification of data centre resilience, from Tier I (basic) to Tier IV (fault tolerant).
- Utility feed
- The supply of electricity from the public grid into a data centre, often two separate feeds from different substations.
V
- VESDA
- An aspirating smoke detector that draws air through a network of pipes to a sensitive laser chamber, sensing smoke long before a fire.
- Virtual PPA
- A financial power contract in which the buyer and a generator settle the difference between a fixed price and the market price, without power changing hands.
W
- Water withdrawal and consumption
- Withdrawal is the water a data centre takes in; consumption is the part that does not return, mostly lost to evaporation.
- White space
- The floor area of a data centre where IT equipment stands: the data halls, as opposed to the plant rooms.
- Wholesale colocation
- Leasing a large block of data centre capacity, a whole hall or building measured in megawatts, to a single tenant on a long contract.
- WUE
- A data centre's yearly water use in litres divided by the energy used by its IT equipment in kilowatt-hours.